Specifications

General Building Information Building Name / Address Bank of America Fifth Avenue Plaza
800 Fifth Avenue
Seattle, Washington Year Built 1981 Year Renovated Lobby Renovation 2001 Design Architect 3D/International, Houston, Texas Developer Gerald D. Hines Owner Block 24 Seattle, Ltd., L.P. Management Company Hines GS Properties, Inc. General Contractor J.A. Jones Construction Co. Mechanical Consultant The Emde Company Electrical Consultant Howard Electric Structural Consultant Skilling, Helle, Christiansen, Robertson, Seattle, Washington Building Type / Use Class A Highrise Office Location 800 Fifth Avenue, between Fifth & Sixth Avenues and Columbia & Marion Streets Structural / Physical Information Total Number of Floors 47 Total Number of Floors Above Grade 43, including Penthouse Total Number of Floors Below Grade 4 Building Height 665 Feet Gross Rentable Area 1,231,663 Square Feet Net Rentable Area 904,784 Square Feet Structure Type Reinforced steel, poured in place concrete columns. Exterior Cladding Annodized aluminium panels and glass curtain wall. Lobby Finishes Flame cut and polished Italian granite with oak ceilings. Hardware Finish Brushed Chrome. Design Live Load 50-80 P.S.I. Number of Passenger Elevators Twenty-Seven (27) Number of Low Rise Elevators Six (6) Number of Mid Rise Elevators Six (6) Number of High Rise Elevators Six (6) plus (1) Shuttle between 41st and 42nd Floors. Number of Freight Elevators Four (4) Number of Garage Elevators Three (3) Parking - Number of Floors Four (4) Parking - Total Number of Spaces 612 Parking - Reserved Contract Rate ($) 330.00 Parking - Unreserved Rate ($) 270.00 Air Distribution Two fans provide 80,000 CFM to two ducts that distribute air to each floor via zone dampers. Building Management System Energency Management System is a Johnson Controls Metasys System. M5 Graphics Operation Display, DX9100 Controllers. Variable frequency drives control outside air fans, air handling units, cooling tower fans, chiller and domestic water pumps. Cooling Capacity Central plant provides 2,500 tons of cooling capacity. Two chill water loops supply 42-46 degrees farenheit chill water to one air handling unit on each floor. Air is distributed via constant velocity fan powered mixing boxes supplying 18-22 zones per floor. Heating Heating is provided by electric strip heaters installed in perimeter zones of each floor. Overtime Air Rate $5.50/hour Zones / Floors 18-25 per floor. Electrical System Design Capabilities 277/480 Volt, 3-Phase Electrical System Emergency Power Diesel Generators: (3) 800 KW, (1) 650KW, (1) 110 KW Electrical System Voltage Four buss-type risers provide 3.33 watts per square foot. Fire Protection System - Type of System Fully sprinklered protection. Fire pump provides 750 gallons of water per minute. Fire monitoring performed by a Notifier AM2020 Fire Alarm Panel. Security - Type of System 24/7 Security Staff on site. CCTV monitoring system for building covering main lobby, elevator lobby landings, loading dock, executive parking and garage elevator lobbies. Building Access Control with card reader system and building exit alarms. Security - Closed Circuit Cameras CCTV monitoring sytem throughout property. Security - Secured Building Access Parking garage security gates are automatically closed at 11 p.m. and re-opened at 6:30 a.m. seven days a week. Access is allowed only to monthly parkers with an active parking access card. Visitors are not allowed access to the garage during these hours. Security - Secured Floor Access Bank of America floors 4-37 are restricted by a card-key system. Employees must have an active identification card to gain access to any Bank of America floors. Security - Security Personnel 24/7 Security Staff Typical Floor Information Typical Floor Size Approximately 21,000 Square Feet Ceiling Height 9 Feet Ceiling Material 2x2 Armstrong Accoustical Tile. Floor Material Poured in place concrete. Restrooms / Floor Tile Window Covering Levellor Blinds
|